PV Module and Component Defects

Standardized Performance Testing

  • STC power measurement (Standard Test Conditions: 25±1°C, 1000 W/m², AM1.5)
  • Low-light measurement (200 W/m²)
  • Matrix measurement (irradiance 100–1300 W/m²)
  • Determination of temperature coefficients
  • Variable flash duration and hysteresis measurement
  • Integrated electroluminescence measurement

Load Testing for Substructure and Module

  • Static mechanical stress test according to customer specifications
  • Static stress test according to IEC 61215-2 MQT 16
  • Dynamic mechanical stress test IEC 61215-2 MQT 20
  • Test to Fail of the substructure including modules
  • Continuous load test at variable temperatures to detect back-side fractures under low load
  • Torsion test

Advanced Standard UV Exposure Tests

  • Standard test for UV-ID sensitivity according to IEC TS 63624-1
  • Pre-stress tests: VI, STC performance measurement, electroluminescence (EL)
  • Initial stabilization
  • UV test: 60 kWh/m²
  • Post-light-soak and dark-storage effects: VI, STC, EL
  • Repeated UV tests and analyses for your module benchmarking

Failure Analysis for Junction Boxes and Connector Pairs

  • X-ray analysis
  • Thermography
  • Non-destructive visualization of failure areas (e.g., defective connectors, cold solder joints)
  • Analytical electron microscopy (structure, corrosion)

Examples of Our Work

 

New standardizable test method for PV module backsheets

Classification of cell tears provides greater legal certainty

Reference Projects

PV-Riss

Assessment of cell cracks in crystalline silicon photovoltaic modules using imaging techniques

 

IndiFiduell

Custom wire-to-finger connections for high-efficiency modules with long-term stability

 

SegmentPV

Higher energy yields by avoiding hotspots

PolymAERA

Standardisierbares Prüfverfahren für PV-Modul-Rückseitenfolien

Anomalous

Detecting module failures in PV systems caused by defective backsheets at an early stage